Ningbo Sanmin Import And Export Co.,Ltd.

Ningbo Sanmin Import And Export Co.,Ltd.

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Pneumatic Solenoid Valve /

MPV Minimum Pressure Control Valve 25mm Orifice

Contact Now
Ningbo Sanmin Import And Export Co.,Ltd.
Visit Website
City:ningbo
Province/State:zhejiang
Country/Region:china
Contact Person:MsIna Chen
Contact Now

MPV Minimum Pressure Control Valve 25mm Orifice

Ask Latest Price
Video Channel
Brand Name :NBSANMINSE
Model Number :MPV-25A
Certification :ISO9001
Place of Origin :CHINA
MOQ :10PCS
Price :Negotiate
Payment Terms :L/C,T/T
Supply Ability :10000PCS
Delivery Time :5-30days
Packaging Details :Box
Orifice :25mm
Opering Pressure :4~5 Bar
Maximum  Pressure :15 Bar
Medium Temp. :-20℃~+120℃
Environment Temp. :-20℃~+60℃
Warranty :1 Year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Minimum pressure valve has the functions of opening/closing,pressure maintaining and backstopping,and offers stable and reliable performance.

MPV Minimum Pressure Control Valve

Model:MPV-25A

Orifice:25mm

Opering Pressure:4~5 Bar

Maximum Pressure:15 Bar

Working Medium Temperature:-20~+120

Working Environment Temperature:-20~+60



Installation Parameters


MPV Minimum Pressure Control Valve 25mm Orifice MPV Minimum Pressure Control Valve 25mm OrificeMPV Minimum Pressure Control Valve 25mm Orifice


A Minimum Pressure Valve (MPV) is a pressure-regulating valve that maintains a minimum pressure in a system, often used in rotary screw air compressors to ensure proper lubrication and protect the air-oil separator. At startup, the MPV is closed to allow pressure to build; once a preset minimum is reached, it opens to allow airflow while its built-in check valve prevents backflow at shutdown, ensuring consistent system operation and longevity.
How it Works
Startup: When the compressor starts, the valve is closed, allowing pressure to build within the air-oil separator.
Opening: As system pressure increases, it overcomes the spring force in the valve, causing it to open.
Full Flow: At normal operating pressure, the valve opens fully, allowing the compressor's output to pass through with minimal pressure loss.
Shutdown: If the system pressure drops below the preset minimum, the valve closes.
Check Valve Function: A separate, integrated check valve then closes to prevent air from flowing backward into the compressor during shutdown.
Key Functions
Oil Lubrication:
The MPV establishes a minimum pressure required for lubricating oil circulation in the compressor.
Component Protection:
It prevents compressor damage and ensures the air-oil separator functions correctly by avoiding excessively low pressure.
Smooth Operation:
By maintaining a stable pressure, the MPV prevents issues like cavitation and contributes to the smooth operation of hydraulic and air systems.
Symptoms of a Faulty MPV
Low oil pressure or low temperatures.
Odd compressor noises.
System instability or inefficienc

Inquiry Cart 0